Testing DECS-250N
Graph Parameters
Any four of the following parameters may be selected for plotting in the graph areas.
Auxiliary voltage input (Vaux)
Average line current (Iavg)
Average line-to-line voltage (Vavg)
AVR error signal (Errln)
AVR output
Bus frequency (B Hz)
Bus voltage (Vbus)
Compensated frequency deviation
(CompF)
Control output (CntOp)
Cross-current input (Iaux)
Droop
FCR error
FCR state
FCR output
Field current (Ifd)
Field voltage (Vfd)
Filtered mechanical power (MechP)
Final PSS output (Pout)
Frequency response signal (Test)
FVR error
FVR state
FVR output
Generator frequency (G Hz)
Internal state (TrnOp)
Lead-lag #1 (x15)
Lead-lag #2 (x16)
Lead-lag #3 (x17)
Lead-lag #4 (x31)
Mechanical power (x10)
Mechanical power (x11)
Mechanical power (x7)
Mechanical power (x8)
Mechanical power (x9)
Negative sequence current (I2)
Negative sequence voltage (V2)
Network Load Share
Null Balance Level (Null Balance)
Null Balance State (Null State)
OEL controller output (OelOutput)
OEL reference
OEL state
Phase A current (Ia)
Phase A to B, line-to-line voltage (Vab)
Phase B current (Ib)
Phase B to C, line-to-line voltage (Vbc)
Phase C current (Ic)
Phase C to A, line-to-line voltage Vca
Position Indication (PositionInd)
Positive sequence current (I1)
Positive sequence voltage (V1)
Post-limit output (Post)
Power factor (PF)
Power HP #1 (x5)
Pre-limit output (Prelim)
PSS electrical power (PSSkW)
PSS terminal voltage (Vtmag)
Reactive power (kvar)
Real power (kW)
SCL controller output (SclOutput)
SCL reference
SCL state
SCL PF reference
Speed HP #1 (x2)
Synthesized speed (Synth)
Terminal frequency deviation (TermF)
Time response signal (Ptest)
Torsional filter #1 (Tflt1)
Torsional filter #2 (x29)
Total power (kVA)
UEL controller output (UelOutput)
UEL reference
UEL state
Var limiter output (VArLimOutput)
Var limiter reference
Var limiter state
Var/PF error
Var/PF state
Var/PF output
Washed out power (WashP)
Washed out speed (WashW)
Frequency Response
Frequency response testing functions are available by clicking the RTM Analysis screen Frequency
Response button. Frequency Response screen functions are illustrated in Figure 160 and described as
follows.
Test Mode
Frequency response testing may be performed in Manual or Auto mode. In Manual mode, a single
frequency can be specified to obtain the corresponding magnitude and phase responses. In Auto mode,