9440500990 Rev D 223
DECS-250N Modbus™ Communication
Group
Name
Register
Type
Bytes
R/W
Unit
Range
AEM Metering
Thermocouple 1 Raw Value
41512
Float
4
R
Millivolt
n/a
AEM Metering
Thermocouple 2 Raw Value
41514
Float
4
R
Millivolt
n/a
AEM Metering
Analog Output 1 Raw Value
41516
Float
4
R
n/a
n/a
AEM Metering
Analog Output 2 Raw Value
41518
Float
4
R
n/a
n/a
AEM Metering
Analog Output 3 Raw Value
41520
Float
4
R
n/a
n/a
AEM Metering
Analog Output 4 Raw Value
41522
Float
4
R
n/a
n/a
AEM Metering
Analog Output 1 Scaled Value
41524
Float
4
R
n/a
n/a
AEM Metering
Analog Output 2 Scaled Value
41526
Float
4
R
n/a
n/a
AEM Metering
Analog Output 3 Scaled Value
41528
Float
4
R
n/a
n/a
AEM Metering
Analog Output 4 Scaled Value
41530
Float
4
R
n/a
n/a
AEM Metering
Thermocouple Input 1 Scaled
Value
41532
Float
4
R
Deg F
n/a
AEM Metering
Thermocouple Input 2 Scaled
Value
41534
Float
4
R
Deg F
n/a
Limiters
Table 28. Limiter Group Parameters
Name
Register
Type
Bytes
R/W
Unit
Range
OEL Primary Current Hi
41700
Float
4
R W
Amp
0 - 30
OEL Primary Current Mid
41702
Float
4
R W
Amp
0 - 20
OEL Primary Current Lo
41704
Float
4
R W
Amp
0 - 15
OEL Primary Time Hi
41706
Float
4
R W
Second
0 - 10
OEL Primary Time Mid
41708
Float
4
R W
Second
0 - 120
OEL Primary Current Hi Off
41710
Float
4
R W
Amp
0 - 30
OEL Primary Current Lo Off
41712
Float
4
R W
Amp
0 - 15
OEL Primary Current Time Off
41714
Float
4
R W
Second
0 - 10
OEL Primary Takeover Current Max Off
41716
Float
4
R W
Amp
0 - 30
OEL Primary Takeover Current Min Off
41718
Float
4
R W
Amp
0 - 15
OEL Primary Takeover Time Dial Off
41720
Float
4
R W
n/a
0.1 - 20
OEL Primary Takeover Current Max On
41722
Float
4
R W
Amp
0 - 30
OEL Primary Takeover Current Min On
41724
Float
4
R W
Amp
0 - 15
OEL Primary Takeover Time Dial On
41726
Float
4
R W
n/a
0.1 - 20
OEL Primary Dvdt Enable
41728
Uint32
4
R W
n/a
Disabled=0 Enabled=1
OEL Primary Dvdt Ref
41730
Float
4
R W
n/a
-10 - 0
OEL Secondary Current Hi
41732
Float
4
R W
Amp
0 - 30
OEL Secondary Current Mid
41734
Float
4
R W
Amp
0 - 20
OEL Secondary Current Lo
41736
Float
4
R W
Amp
0 - 15
OEL Secondary Time Hi
41738
Float
4
R W
Second
0 - 10
OEL Secondary Time Mid
41740
Float
4
R W
Second
0 - 120
OEL Secondary Current Hi Off
41742
Float
4
R W
Amp
0 - 30
OEL Secondary Current Lo Off
41744
Float
4
R W
Amp
0 - 15
OEL Secondary Current Time Off
41746
Float
4
R W
Second
0 - 10
OEL Secondary Takeover Current Max Off
41748
Float
4
R W
Amp
0 - 30
OEL Secondary Takeover Current Min Off
41750
Float
4
R W
Amp
0 15
OEL Secondary Takeover Time Dial Off
41752
Float
4
R W
n/a
0.1 20
OEL Secondary Takeover Current Max On
41754
Float
4
R W
Amp
0 30
OEL Secondary Takeover Current Min On
41756
Float
4
R W
Amp
0 15
OEL Secondary Takeover Time Dial On
41758
Float
4
R W
n/a
0.1 20