224 9369700990 Rev R
Registers
Data Description
Access
Data
Format
42608
Defined
42609
Loop gain for var limiter
RW
FLOAT
42611
Integral gain for var limiter
RW
FLOAT
42613 to
42675
Reserved for future C8 use
Not
Defined
42676
Secondary Stability Range (Gain Table Index)
RW
FLOAT
42678
Secondary AVR - Proportional Gain Kp
RW
FLOAT
42680
Secondary AVR - Integral Gain Ki
RW
FLOAT
42682
Secondary AVR - Derivative Gain Kd
RW
FLOAT
42684
Secondary AVR - Loop Gain Kg
RW
FLOAT
42686
Secondary AVR - Derivative Time Constant Td
RW
FLOAT
42688 to
42999
Reserved for future C8 use
R
Not
Defined
Holding Registers for Protection Function Parameters
Table 43. Information Category C9Protection Function Parameters
Registers
Data Description
Access
Data
Format
43001
Primary Exciter Field Overvoltage
RW
UINT16
43002
Primary Exciter Field Overcurrent
RW
UINT16
43003
Primary Generator Undervoltage
RW
UINT16
43004
Primary Generator Overvoltage
RW
UINT16
43005
Primary Field Over Temperature
RW
UINT16
43006
Primary Loss of Field
RW
UINT16
43007
Primary Loss of Field Isolation Transducer
RW
UINT16
43008
Primary Power Low
RW
UINT16
43009
24 Volts/Hz
RW
UINT16
43010 to
43012
Not used
R
Not
Defined
43013
Inverse Time Curve Exponent
RW
UINT16
43014 to
43024
Not used
R
Not
Defined
43025
Active Protection Setting Group
R
UINT16
43026
Primary Field Overvoltage Level
RW
FLOAT
43028
Primary Field Overcurrent Level
RW
FLOAT
43030
Primary Generator Undervoltage Level
RW
FLOAT
43032
Primary Generator Overvoltage Level
RW
FLOAT
43034
Primary Field Overvoltage Time Delay
RW
FLOAT
43036
Primary Field Overcurrent Time Dial
RW
FLOAT
43038
Primary Generator Undervoltage Time Delay
RW
FLOAT
43040
Primary Generator Overvoltage Time Delay
RW
FLOAT
43042
Primary Field Over Temperature Level
RW
FLOAT
43044
Primary Field Over Temperature Time Delay
RW
FLOAT
43046
Primary Loss of Field Level
RW
FLOAT
43048
Primary Loss of Field Time Delay
RW
FLOAT
43050
Primary Loss of Field Isolation Transducer Level
R
FLOAT
43052
Primary Loss of Field Isolation Transducer Time Delay
RW
FLOAT
43054
Primary Power Low Level
R
FLOAT
43056
Primary Power Low Time Delay
R
FLOAT
43058 to
43124
Reserved for future C9 use
R
Not
Defined
43126
Secondary Exciter Field Overvoltage
R
UINT16
43127
Secondary Exciter Field Overcurrent
R
UINT16
Modbus™ Communication DECS-400